During the installation of the ATOS Solenoid Valve DLEH-3C 20, it is important to follow these tips to ensure that the valve functions properly. The direction of flow of the medium should be carefully checked so that the arrow on the valve body points in the correct direction. Additionally, the solenoid valve should be installed in a location where there is no direct exposure to dripping water or splashed water.
Enviar inquérito
Introdução de Produto

 

ATOS Solenoid Valve DLEH-3C 20 Installation Tips:
1. During installation, make sure that the arrow on the valve body points in the direction of the flow of the medium. It should not be installed in places with direct exposure to dripping or splashing water. The solenoid valve should be installed vertically upwards.
2. The solenoid valve should be ensured to work normally within 15%-10% fluctuation range of the rated voltage.
3. After installation, there should be no reverse pressure difference in the pipeline. The solenoid valve should be powered on a few times and allowed to reach operating temperature before being put into formal use.
4. Before installing the solenoid valve, the pipeline should be thoroughly cleaned and the medium entering it should be free of impurities. Install a filter in front of the valve.
5. In order to ensure the normal operation of the system during solenoid valve failure or cleaning, a bypass device should be installed.
During the installation of the ATOS Solenoid Valve DLEH-3C 20, it is important to follow these tips to ensure that the valve functions properly. The direction of flow of the medium should be carefully checked so that the arrow on the valve body points in the correct direction. Additionally, the solenoid valve should be installed in a location where there is no direct exposure to dripping water or splashed water.
Ensuring that the solenoid valve is operating within the correct voltage range is also important. A fluctuation of 15%-10% of the rated voltage is acceptable, but beyond that range, the valve may not function properly.
Before putting the solenoid valve into formal use, it should be powered on a few times to allow it to reach operating temperature. This will help to ensure that the valve operates smoothly and effectively.
The pipeline should be thoroughly cleaned before installation to remove any impurities, and a filter should be installed in front of the valve to prevent any debris or other contaminants from entering the pipeline.
Finally, it is recommended to install a bypass device in order to ensure the normal operation of the system during solenoid valve failure or cleaning. By following these tips, the ATOS Solenoid Valve DLEH-3C 20 can be installed correctly and function effectively.

 

 

 

 

 

DLHZO-T-060-L51/B DLKZA-T-140-L71/PA-GK/7
DLHZO-TE-040-L71 DLKZOR-T-140-L71
DLHZO-TE-040-L71 DLKZOR-T-140-L73
DLHZO-TE-040-L71/40 DLKZOR-T-140-L73
DLHZO-TE-040-L71 DLKZOR-TE-140-L33/I
DLHZO-TE-040-L71 DLKZOR-TE-140-L33/I
DLHZO-TE-040-L71/I DLKZOR-TE-140-L73/I
DLHZO-TE-040-L71/I/PE DLKZOR-TE-140-L71
DLHZO-TE-040-L71/I/PE DLKZOR-TE-140-L71
DLHZO-TE-040-L73/B DLKZOR-TE-140-L71
DLHZO-TE-040-L73 DLKZOR-TE-140-L73
DLHZO-TE-040-L73/40 DLKZOR-TE-140-L71/I
DLHZO-TE-040-L73/Q DLKZOR-TE-140-L71/I
DLHZO-TE-040-L73/I DLKZOR-TE-140-L71/I
DLHZO-TE-040-L73/Z DLKZOR-TE-140-L71/FI
DLHZO-TE-040-V31/B 40 DLKZOR-TE-140-L73 41
DLHZO-TES-SN-NP-060-L71 DLKZOR-TE-160-L71
DLHZO-TES-SF-NP-060-L71/BCI DLKZOR-TES-PS-140-D73/I 42
DLHZO-LE-040-L03 DLKZOR-TES-SN-NP-160-L73/Y
DLKZO-T-140-L71  


 

 

CO-BRANDING

 

QQ20241009115201

 

 

QQ202409251733331

102 -

 

103

 

105 -

 

106

 

107

108 -

 

Tag: DLEHM3CX Series Solenoid Directional Valve, China DLEHM3CX Series Solenoid Directional Valve manufacturers, suppliers, factory

Enviar inquérito

whatsapp

Telefone

Email

Inquérito